1.
Neuroimage Clin ; 14: 195-200, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28180078

RESUMO

There is ample evidence that the inhibitory GABA and the excitatory glutamate system are essential for an adequate response to stress. Both GABAergic and glutamatergic brain circuits modulate hypothalamus-pituitary-adrenal (HPA)-axis activity, and stress in turn affects glutamate and GABA levels in the rodent brain. However, studies examining stress-induced GABA and glutamate levels in the human brain are scarce. Therefore, we investigated the influence of acute psychosocial stress (using the Trier Social Stress Test) on glutamate and GABA levels in the medial prefrontal cortex of 29 healthy male individuals using 7 Tesla proton magnetic resonance spectroscopy. In vivo GABA and glutamate levels were measured before and 30 min after exposure to either the stress or the control condition. We found no associations between psychosocial stress or cortisol stress reactivity and changes over time in medial prefrontal glutamate and GABA levels. GABA and glutamate levels over time were significantly correlated in the control condition but not in the stress condition, suggesting that very subtle differential effects of stress on GABA and glutamate across individuals may occur. However, overall, acute psychosocial stress does not appear to affect in vivo medial prefrontal GABA and glutamate levels, at least this is not detectable with current practice 1H-MRS.


Assuntos
Ácido Glutâmico/metabolismo , Córtex Pré-Frontal/metabolismo , Espectroscopia de Prótons por Ressonância Magnética , Estresse Psicológico/diagnóstico por imagem , Ácido gama-Aminobutírico/metabolismo , Doença Aguda , Adolescente , Adulto , Feminino , Humanos , Hidrocortisona/sangue , Masculino , Córtex Pré-Frontal/diagnóstico por imagem , Escalas de Graduação Psiquiátrica , Estresse Psicológico/sangue , Inquéritos e Questionários , Adulto Jovem
2.
Med Phys ; 43(7): 4375, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27370152

RESUMO

PURPOSE: The high precession frequency in ultrahigh field MRI coincides with reduced RF penetration, increased RF power deposition and consequently can lead to reduced scan efficiency. However, the shorter wavelength enables the use of efficient antennas rather than loop coils. In fact, ultrathin monopole antennas have been demonstrated at 7 T, which fit in natural cavities like the rectum in the human body. As the RF field generated by the antenna provides an extremely nonuniform B1 field, the use of conventional RF pulses will lead to severe image distortions and highly nonuniform contrast. However, using the two predominant dimensions (orthogonal to the antenna), 2D RF pulses can be designed that counteract the nonuniform B1 into uniform flip angles. In this study the authors investigate the use of an ultrathin antenna not only for reception, but also for transmission in 7 T MRI of the rectum. METHODS: The 2D radially compensating excitation (2D RACE) pulse was designed in matlab. SAR calculations between the 2D RACE pulse and an adiabatic RF pulse (BIR-4) have been obtained, to visualize the gain in decreasing the SAR when using the 2D RACE pulse instead of an adiabatic RF pulse. The authors used the 7 T whole body MR system in combination with an internally placed monopole antenna used for transceiving and obtained 3D gradient echo images with a conventional sinc pulse and with the 2D RACE pulse. For extra clarity, they also reconstructed an image where the receive field of the antenna was removed. RESULTS: Comparing the results of the SAR simulations of the 2D RACE pulse with a BIR-4 pulse shows that for low flip angles (θ < 41°) the SAR can be decreased with a factor of 4.8 or even more, when using the 2D RACE pulse. Relative to a conventional sinc excitation, the 2D RACE pulse achieves more uniform flip angle distributions than a BIR-4 pulse with a smaller SAR increase (16 × versus 64 ×). CONCLUSIONS: The authors have shown that the 2D RACE pulse provides more homogeneous flip angles for gradient echo sequences when compared to a conventional sinc pulse albeit at increased SAR. However, when compared to adiabatic RF pulses, as shown by simulations, the SAR of the 2D RACE pulse can be an order of magnitude less. Phantom and in vivo human rectum images are obtained to demonstrate that the 2D RACE pulse can provide a uniform excitation while transmitting with a single ultrathin endorectal antenna at 7 T. The combination of thin rectal antennas with efficient uniform transmit can open up new possibilities in high resolution imaging of rectal cancer.


Assuntos
Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Reto/diagnóstico por imagem , Algoritmos , Simulação por Computador , Desenho de Equipamento , Humanos , Modelos Anatômicos , Imagens de Fantasmas , Software
3.
NMR Biomed ; 29(9): 1231-9, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27191947

RESUMO

Multimodal MRI is the state of the art method for clinical diagnostics and therapy monitoring of the spinal cord, with MRS being an emerging modality that has the potential to detect relevant changes of the spinal cord tissue at an earlier stage and to enhance specificity. Methodological challenges related to the small dimensions and deep location of the human spinal cord inside the human body, field fluctuations due to respiratory motion, susceptibility differences to adjacent tissue such as vertebras and pulsatile flow of the cerebrospinal fluid hinder the clinical application of (1) H MRS to the human spinal cord. Complementary to previous studies that partly addressed these problems, this work aims at enhancing the signal-to-noise ratio (SNR) of (1) H MRS in the human spinal cord. To this end a flexible tight fit high density receiver array and ultra-high field strength (7 T) were combined. A dielectric waveguide and dipole antenna transmission coil allowed for dual channel RF shimming, focusing the RF field in the spinal cord, and an inner-volume saturated semi-LASER sequence was used for robust localization in the presence of B1 (+) inhomogeneity. Herein we report the first 7 T spinal cord (1) H MR spectra, which were obtained in seven independent measurements of 128 averages each in three healthy volunteers. The spectra exhibit high quality (full width at half maximum 0.09 ppm, SNR 7.6) and absence of artifacts and allow for reliable quantification of N-acetyl aspartate (NAA) (NAA/Cr (creatine) 1.31 ± 0.20; Cramér-Rao lower bound (CRLB) 5), total choline containing compounds (Cho) (Cho/Cr 0.32 ± 0.07; CRLB 7), Cr (CRLB 5) and myo-inositol (mI) (mI/Cr 1.08 ± 0.22; CRLB 6) in 7.5 min in the human cervical spinal cord. Thus metabolic information from the spinal cord can be obtained in clinically feasible scan times at 7 T, and its benefit for clinical decision making in spinal cord disorders will be investigated in the future using the presented methodology. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Espectroscopia de Prótons por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Medula Espinal/metabolismo , Transdutores , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Aumento da Imagem/instrumentação , Campos Magnéticos , Masculino , Doses de Radiação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Medula Espinal/anatomia & histologia
4.
Magn Reson Med ; 74(3): 599-606, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26151840

RESUMO

PURPOSE: To develop the simultaneous acquisition of multiple voxels in localized MR spectroscopy (MRS) using sensitivity encoding, allowing reduced total scan time compared to conventional sequential single voxel (SV) acquisition methods. METHODS: Dual volume localization was used to simultaneously excite voxels in both hemispheres. Receiver coil sensitivity profiles were used to unfold the data. To demonstrate the method, MRS voxels in the left and right hippocampus were measured at 3 tesla (T) and the left and right motor cortices at 7T. Spectra were compared to conventional SV acquisitions. Spectra were also recorded from the lesion and contralateral hemisphere of a patient with a low-grade oligodendroglioma at 7T. RESULTS: It was possible to generate signal in two voxels simultaneously and separate the signal originating from the different locations, with spectral results almost identical to those observed using conventional single voxel methods. The method results in an increased chemical shift displacement artifact, which might be improved by advanced pulse designs, and a noise increase due to the unfolding g-factor, which was larger at 3T than 7T. CONCLUSION: The simultaneous acquisition of voxels for MRS is possible by using modulated slice-selective pulses and receive coil sensitivity profiles to unfold the resulting signals.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Encéfalo/patologia , Neoplasias Encefálicas/patologia , Humanos , Oligodendroglioma/patologia , Imagens de Fantasmas
5.
NMR Biomed ; 28(4): 514-22, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25802216

RESUMO

Lactate levels are measurable by MRS and are related to neural activity. Therefore, it is of interest to accurately measure lactate levels in the basal ganglia networks. If sufficiently stable, lactate measurements may be used to investigate alterations in dopaminergic signalling in the striatum, facilitating the detection and diagnosis of metabolic deficits. The aim of this study is to provide a J-difference editing MRS technique for the selective editing of lactate only, thus allowing the detection of lactate without contamination of overlapping macromolecules. As a validation procedure, macromolecule nulling was combined with J-difference editing, and this was compared with J-difference editing with a new highly selective editing pulse. The use of a high-field (7T) MR scanner enables the application of editing pulses with very narrow bandwidth, which are selective for lactate. We show that, despite the sensitivity to B0 offsets, the use of a highly selective editing pulse is more efficient for the detection of lactate than the combination of a broad-band editing pulse with macromolecule nulling. Although the signal-to-noise ratio of uncontaminated lactate detection in healthy subjects is relatively low, this article describes the test-retest performance of lactate detection in the striatum when using highly selective J-difference editing MRS at 7 T. The coefficient of variation, σw and intraclass correlation coefficients for within- and between-subject differences of lactate were determined. Lactate levels in the left and right striatum were determined twice in 10 healthy volunteers. Despite the fact that the test-retest performance of lactate detection is moderate with a coefficient of variation of about 20% for lactate, these values can be used for the design of new studies comparing, for example, patient populations with healthy controls.


Assuntos
Corpo Estriado/química , Ácido Láctico/análise , Espectroscopia de Ressonância Magnética , Adulto , Ácido Aspártico/análogos & derivados , Ácido Aspártico/análise , Gânglios da Base/química , Colina/análise , Creatina/análise , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/estatística & dados numéricos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
6.
NMR Biomed ; 28(3): 306-16, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25581510

RESUMO

The purpose of this work was to harmonize data acquisition and post-processing of single voxel proton MRS ((1) H-MRS) at 7 T, and to determine metabolite concentrations and the accuracy and reproducibility of metabolite levels in the adult human brain. This study was performed in compliance with local institutional human ethics committees. The same seven subjects were each examined twice using four different 7 T MR systems from two different vendors using an identical semi-localization by adiabatic selective refocusing spectroscopy sequence. Neurochemical profiles were obtained from the posterior cingulate cortex (gray matter, GM) and the corona radiata (white matter, WM). Spectra were analyzed with LCModel, and sources of variation in concentrations ('subject', 'institute' and 'random') were identified with a variance component analysis. Concentrations of 10-11 metabolites, which were corrected for T1 , T2 , magnetization transfer effects and partial volume effects, were obtained with mean Cramér-Rao lower bounds below 20%. Data variances and mean concentrations in GM and WM were comparable for all institutions. The primary source of variance for glutamate, myo-inositol, scyllo-inositol, total creatine and total choline was between subjects. Variance sources for all other metabolites were associated with within-subject and system noise, except for total N-acetylaspartate, glutamine and glutathione, which were related to differences in signal-to-noise ratio and in shimming performance between vendors. After multi-center harmonization of acquisition and post-processing protocols, metabolite concentrations and the sizes and sources of their variations were established for neurochemical profiles in the healthy brain at 7 T, which can be used as guidance in future studies quantifying metabolite and neurotransmitter concentrations with (1) H-MRS at ultra-high magnetic field.


Assuntos
Encéfalo/metabolismo , Metaboloma , Adulto , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Modelos Teóricos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
7.
NMR Biomed ; 27(11): 1353-60, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25212868

RESUMO

Spectral degradations as a result of temporal field variations are observed in MRSI of the human prostate. Moving organs generate substantial temporal and spatial field fluctuations as a result of susceptibility mismatch with the surrounding tissue (i.e. periodic breathing, cardiac motion or random bowel motion). Nine patients with prostate cancer were scanned with an endorectal coil (ERC) on a 7-T MR scanner. Temporal B0 field variations were observed with fast dynamic B0 mapping in these patients. Simulations of dynamic B0 corrections were performed using zero- to second-order shim terms. In addition, the temporal B0 variations were applied to simulated MR spectra causing, on average, 15% underestimation of the choline/citrate ratio. Linewidth distortions and frequency shifts (up to 30 and 8 Hz, respectively) were observed. To demonstrate the concept of observing local field fluctuations in real time during MRSI data acquisition, a field probe (FP) tuned and matched for the (19) F frequency was incorporated into the housing of the ERC. The data acquired with the FP were compared with the B0 field map data and used to correct the MRSI datasets retrospectively. The dynamic B0 mapping data showed variations of up to 30 Hz (0.1 ppm) over 72 s at 7 T. The simulated zero-order corrections, calculated as the root mean square, reduced the standard deviation (SD) of the dynamic variations by an average of 41%. When using second-order corrections, the reduction in the SD was, on average, 56%. The FP data showed the same variation range as the dynamic B0 data and the variation patterns corresponded. After retrospective correction, the MRSI data showed artifact reduction and improved spectral resolution. B0 variations can degrade the MRSI substantially. The simple incorporation of an FP into an ERC can improve prostate cancer MRSI without prior knowledge of the origin of the dynamic field distortions.


Assuntos
Adenocarcinoma/química , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Próstata/química , Neoplasias da Próstata/química , Adenocarcinoma/diagnóstico , Adenocarcinoma/patologia , Algoritmos , Artefatos , Colina/análise , Citratos/análise , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Masculino , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Reto , Fatores de Tempo
8.
NMR Biomed ; 27(10): 1248-55, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25146680

RESUMO

Here, we show that the sensitivity of (31)P MRSI of (31)P spins J-coupled to protons can be increased by almost a factor of three when compared with an optimal direct detection free induction decay. By direct detection integrated with multi-echo polarization transfer (DIMEPT), multiple signals from polarization transfer and direct detection can be acquired in one repetition time, with minimal mutual interference, provided that the number of refocusing pulses in the multi-echo polarization transfer part is even. The DIMEPT sequence was implemented on a 7-T body scanner and tested on a phantom and on the breasts of five healthy volunteers. The in vivo signal-to-noise ratio (SNR) enhancement for the J-coupled phosphomonoesters was 270% when compared with an Ernst angle pulse-acquire sequence. However, the phosphodiester signals, presumably mainly mobile phospholipids, had T2 values that were too short to be enhanced. Uncoupled (31)P spins, with sufficiently long T2 values, such as inorganic phosphate, were SNR enhanced by a factor of 1.9 relative to an Ernst-angle excitation pulse-acquire sequence by multi-echo direct detection.


Assuntos
Mama/química , Espectroscopia de Ressonância Magnética/métodos , Adulto , Algoritmos , Etanolaminas/análise , Feminino , Glicerilfosforilcolina/análise , Humanos , Isótopos de Fósforo , Fosforilcolina/análise , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
9.
Magn Reson Med ; 71(4): 1641-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23788130

RESUMO

PURPOSE: Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilitates RF shimming based on the traveling waves. METHODS: The multimode, coaxial waveguide combines the coaxial waveguide, cylindrical waveguide, high dielectric permittivity lining, and eight radial stub antennas. Each antenna excites multiple waveguide modes. Based on modes orthogonality, a method was devised to decompose an excitation pattern of single stub antenna into waveguide modes. RESULTS: The number of modes present in the excitation pattern of a single stub antenna increased with the higher effective permittivity of the dielectric lining. Thus, RF shimming performance of the setup was improved. An average homogeneity of 10% was demonstrated for a single slice of each principle plane in the human head at 7 T. CONCLUSION: Traveling wave RF shimming is feasible both in axial and longitudinal directions and is improved with an increased amount of orthogonal waveguide modes. Nevertheless, with the currently available RF amplifiers at 7 T, the performance of the setup is limited to low flip angles.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Transdutores , Imagem Corporal Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Campos Magnéticos , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
10.
NMR Biomed ; 26(11): 1596-601, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23893556

RESUMO

A method to measure the T2 relaxation time of GABA with spectral editing techniques is proposed. Spectral editing techniques can be used to unambiguously extract signals of low concentration J-coupled spins such as γ-aminobutyric acid (GABA) from overlapping resonances such as creatine and macromolecules. These sequences, however, generally have fixed and relatively long echo times. Therefore, for the absolute quantification of the edited spectrum, the T2 relaxation time must be taken into account. To measure the T2 relaxation time, the signal intensity has to be obtained at multiple echo times. However, on a coupled spin system such as GABA this is challenging, since the signal intensity of the target resonances is modulated not only by T2 decay but also by the J-coupling, which strongly influences the shapes and amplitudes of the edited signals, depending on the echo time. Here, we propose to refocus the J-modulation of the edited signal at different echo times by using chemical shift selective refocusing. In this way the echo time can be arbitrarily extended while preserving the shape of the edited signal. The method was applied in combination with the MEGA-sLASER editing technique to measure the in vivo T2 relaxation time of GABA (87 ± 11 ms, n = 10) and creatine (109 ± 8 ms, n = 10) at 7 T. The T1 relaxation time of these metabolites in a single subject was also determined (GABA, 1334 ± 158 ms; Cr, 1753 ± 12 ms). The T2 decay curve of coupled spin systems can be sampled in an arbitrary fashion without the need for signal shape correction. Furthermore, the method can be applied with any spectral editing technique. The shortest echo time of the method is limited by the echo time of the spectral editing technique.


Assuntos
Imageamento por Ressonância Magnética , Ácido gama-Aminobutírico/metabolismo , Creatina/metabolismo , Humanos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Fatores de Tempo
11.
NMR Biomed ; 26(10): 1299-307, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23553945

RESUMO

An adiabatic multi-echo spectroscopic imaging (AMESING) sequence, used for (31) P MRSI, with spherical k-space sampling and compensated phase-encoding gradients, was implemented on a whole-body 7-T MR system. One free induction decay (FID) and up to five symmetric echoes can be acquired with this sequence. In tissues with low T2 and high T2 , this can theoretically lead to a potential maximum signal-to-noise ratio (SNR) increase of almost a factor of three, compared with a conventional FID acquisition with Ernst-angle excitation. However, with T2 values being, in practice, ≤400 ms, a maximum enhancement of approximately two compared with low flip Ernst-angle excitation should be feasible. The multi-echo sequence enables the determination of localized T2 values, and was validated with (31) P three-dimensional MRSI on the calf muscle and breast of a healthy volunteer, and subsequently applied in a patient with breast cancer. The T2 values of phosphocreatine, phosphodiesters (PDE) and inorganic phosphate in calf muscle were 193 ± 5 ms, 375 ± 44 ms and 96 ± 10 ms, respectively, and the apparent T2 value of γ-ATP was 25 ± 6 ms. A T2 value of 136 ± 15 ms for inorganic phosphate was measured in glandular breast tissue of a healthy volunteer. The T2 values of phosphomonoesters (PME) and PDE in breast cancer tissue (ductulolobular carcinoma) ranged between 170 and 210 ms, and the PME to PDE ratios were calculated to be phosphoethanolamine/glycerophosphoethanolamine = 2.7, phosphocholine/glycerophosphocholine = 1.8 and PME/PDE = 2.3. Considering the relatively short T2 values of the metabolites in breast tissue at 7 T, the echo spacing can be short without compromising spectral resolution, whilst maximizing the sensitivity.


Assuntos
Mama/anatomia & histologia , Espectroscopia de Ressonância Magnética , Músculos/anatomia & histologia , Fósforo/metabolismo , Adiposidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído , Fatores de Tempo , Água
12.
NMR Biomed ; 26(10): 1213-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23508792

RESUMO

γ-Aminobutyric acid (GABA) and lactate are metabolites which are present in the brain. These metabolites can be indicators of psychiatric disorders or tumor hypoxia, respectively. The measurement of these weakly coupled spin systems can be performed using MRS editing techniques; however, at high field strength, this can be challenging. This is due to the low available B1 (+) field at high fields, which results in narrow-bandwidth refocusing pulses and, consequently, in large chemical shift displacement artifacts. In addition, as a result of the increased chemical shift displacement artifacts and chemical shift dispersion, the efficiency of the MRS method is reduced, even when using adiabatic refocusing pulses. To overcome this limitation, frequency offset corrected inversion (FOCI) pulses have been suggested as a mean to substantially increase the bandwidth of adiabatic pulses. In this study, a Mescher-Garwood semi-localization by adiabatic selection and refocusing (MEGA-sLASER) editing sequence with refocusing FOCI pulses is presented for the measurement of GABA and lactate in the human brain. Metabolite detection efficiencies were improved by 20% and 75% for GABA and lactate, respectively, when compared with editing techniques that employ adiabatic radiofrequency refocusing pulses. The highly efficient MEGA-sLASER sequence with refocusing FOCI pulses is an ideal and robust MRS editing technique for the measurement of weakly coupled metabolites at high field strengths.


Assuntos
Ácido Láctico/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Ácido gama-Aminobutírico/metabolismo , Encéfalo/metabolismo , Humanos , Imageamento Tridimensional , Ondas de Rádio
13.
NMR Biomed ; 26(4): 367-75, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23076877

RESUMO

There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV.


Assuntos
Mama/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Aceleração , Adulto , Meios de Contraste , Feminino , Humanos , Ondas de Rádio , Razão Sinal-Ruído , Fatores de Tempo
14.
Magn Reson Med ; 68(2): 353-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22162118

RESUMO

The sensitivity of (31)P MRS can be increased using higher magnetic fields, but also by using (1)H to (31)P polarization transfer techniques where the sensitivity is determined by the polarization of the proton spins and thus the signal-to-noise per unit time is unaffected by the slow T(1) relaxation properties of the (31)P spins. This implies that (31)P spins can be manipulated during the T(1) relaxation of the (1)H spins without affecting the signal-to-noise of the (1)H to (31)P polarization transferred spins. It is shown here that by combining (1)H to (31)P polarization transfer with a direct (31)P detection sequence in one repetition time, one can gain more signal-to-noise per unit of time as compared to a polarization transfer sequence alone. Proof of principle was demonstrated by phantom measurements and additionally the method was applied to the human calf muscle and to the human breast in vivo at 7 T.


Assuntos
Algoritmos , Mama/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Músculo Esquelético/metabolismo , Isótopos de Fósforo/análise , Processamento de Sinais Assistido por Computador , Ésteres , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
15.
Vet J ; 192(1): 81-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21636298

RESUMO

Brain perfusion can be investigated using single photon emission computed tomography (SPECT) and the intravenous injection of (99m)technetium ethyl cysteinate dimer ((99m)Tc-ECD). However, sedation using medetomidine, an α(2)-agonist, or anaesthesia using medetomidine and ketamine, an N-methyl-d-aspartate-(NMDA)-antagonist, may be required for SPECT studies in cats but can affect the regional cerebral blood flow (rCBF). The effects of medetomidine, with or without ketamine, on regional brain perfusion were therefore investigated in six cats under three conditions. Injection of tracer occurred before sedation or anaesthesia (condition A), following intramuscular (IM) sedation with medetomidine (condition M) or after IM anaesthesia with medetomidine and ketamine (condition MK). Medetomidine and medetomidine with ketamine caused a significantly higher total tracer uptake in all brain regions. Semi-quantification of brain perfusion gave lower perfusion indices in several sub-cortical regions in conditions M and MK, compared to A. Left-right differences were observed in the temporal cortex (A), the temporal, parietal cortex and the thalamus (M) and the frontal cortex (MK). A significantly higher perfusion index in the sub-cortical regions, compared to the whole cortex, was only present in condition A. This study showed that caution is needed when quantifying brain perfusion indices when using sedative or anaesthetic agents that may affect rCBF.


Assuntos
Anestésicos Dissociativos/administração & dosagem , Gatos/metabolismo , Circulação Cerebrovascular/efeitos dos fármacos , Hipnóticos e Sedativos/administração & dosagem , Ketamina/administração & dosagem , Medetomidina/administração & dosagem , Animais , Tempo de Circulação Sanguínea/veterinária , Estudos Cross-Over , Cisteína/análogos & derivados , Combinação de Medicamentos , Feminino , Injeções Intramusculares/veterinária , Injeções Intravenosas/veterinária , Imageamento por Ressonância Magnética/veterinária , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/veterinária
16.
NMR Biomed ; 24(9): 1038-46, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21294206

RESUMO

In vivo MRS of the human brain at ultrahigh field allows for the identification of a large number of metabolites at higher spatial resolutions than currently possible in clinical practice. However, the in vivo localization of single-voxel spectroscopy has been shown to be challenging at ultrahigh field because of the low bandwidth of refocusing radiofrequency (RF) pulses. Thus far, the proposed methods for localized MRS at 7 T suffer from long TE, inherent signal loss and/or a large chemical shift displacement artifact that causes a spatial displacement between resonances, and results in a decreased efficiency in editing sequences. In this work, we show that, by driving a standard volume coil with two RF amplifiers, focusing the B 1+ field in a certain location and using high-bandwidth adiabatic refocusing pulses, a semi-LASER (semi-localized by adiabatic selective refocusing) localization is feasible at short TE in the human brain with full signal acquisition and a low chemical shift displacement artifact at 7 T.


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Prótons , Ondas de Rádio , Absorção , Simulação por Computador , Campos Eletromagnéticos , Humanos , Metaboloma , Marcadores de Spin
17.
NMR Biomed ; 24(3): 299-306, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20925128

RESUMO

(1)H MRSI is often used at 1.5 or 3 T to study prostate cancer, where the ratio of choline + creatine to citrate is taken as a marker for tumour presence. Recently, the level of polyamines (mainly spermine) has been shown to improve specificity even further. However, the in vivo detection of these polyamines (at 3.1 ppm) is hampered by signal cancellation as a result of J-coupling effects and signal overlap with choline (3.2 ppm) and creatine (3.0 ppm) resonances. At higher magnetic field strengths, the chemical shift dispersion will increase, which allows the use of very selective radiofrequency pulses to refocus J-coupled spins. In this work, we added selective refocusing pulses to a semi-LASER (localisation based on adiabatic selective refocusing) sequence at 7 T, and optimised the inter-pulse timings of the sequence for fully refocused detection of spermine spins, whilst maintaining optimised detection of choline, creatine and the strongly coupled spin system of citrate.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Poliaminas/química , Poliaminas/metabolismo , Neoplasias da Próstata/química , Neoplasias da Próstata/metabolismo , Biomarcadores Tumorais/química , Biomarcadores Tumorais/metabolismo , Colina/química , Ácido Cítrico/química , Creatina/química , Humanos , Masculino , Neoplasias da Próstata/diagnóstico , Sensibilidade e Especificidade
18.
NMR Biomed ; 23(8): 995-1000, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20878975

RESUMO

Non-invasive determination of mitochondrial content is an important objective in clinical and sports medicine. 31P MRS approaches to obtain information on this parameter at low field strength typically require in-magnet exercise. Direct observation of the intra-mitochondrial inorganic phosphate (Pi) pool in resting muscle would constitute an alternative, simpler method. In this study, we exploited the higher spectral resolution and signal-to-noise at 7T to investigate the MR visibility of this metabolite pool. 31P in vivo MR spectra of the resting soleus (SOL) muscle were obtained with 1H MR image-guided surface coil localization (six volunteers) and of the SOL and tibialis anterior (TA) muscle using 2D CSI (five volunteers). A resonance at a frequency 0.38 ppm downfield from the cytosolic Pi resonance (Pi(1); pH 7.0 ± 0.04) was reproducibly detected in the SOL muscle in all subjects and conditionally attributed to the intra-mitochondrial Pi pool (Pi(2); pH 7.3 ± 0.07). In the SOL muscle, the Pi(2)/Pi(1) ratio was 1.6 times higher compared to the TA muscle in the same individual. Localized 3D CSI results showed that the Pi(2) peak was present in voxels well away from blood vessels. Determination of the T1 of the two Pi pools in a single individual using adiabatic excitation of the spectral region around 5 ppm yielded estimates of 4.3 ± 0.4 s vs 1.4 ± 0.5 s for Pi(1) and Pi(2), respectively. Together, these results suggest that the intra-mitochondrial Pi pool in resting human skeletal muscle may be visible with 31P MRS at high field.


Assuntos
Exercício Físico/fisiologia , Espectroscopia de Ressonância Magnética/métodos , Músculo Esquelético , Fosfatos/análise , Isótopos de Fósforo , Descanso , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mitocôndrias/metabolismo , Músculo Esquelético/química , Músculo Esquelético/citologia , Músculo Esquelético/metabolismo , Isótopos de Fósforo/química , Isótopos de Fósforo/metabolismo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...